Simulink coder and naming of initial condition load variable

조회 수: 1 (최근 30일)
Nicolas B
Nicolas B 2025년 2월 21일
댓글: Nicolas B 2025년 2월 21일
Hi,
I am generating code from Simulink and when I use the enabled subsystem, sometimes, I set "states when enabling" to reset. That's a convenient way to reset all states in the subsystem without creating a signal for that and works very well. Btw, I am also using that with the if statement "architecture".
There is only 1 "small difficulty" I have. In the generated code, I get 1 variable named "icload_xyz" per state I have in the subsystem. So if I have for example 3 delay blocks, I will have "icload_a", "icload_b" and "icload_c" added to the generated code.
Does someone with experience knows how to:
  1. define the same of these variables.
  2. have 1 variable per enabled subsystem (or if subsystem).
Thank you for your help.
Regards, Nicolas
  댓글 수: 2
Fangjun Jiang
Fangjun Jiang 2025년 2월 21일
If you have three states then you need to have three varialbes, right?
If not, can you explain how it can be done if you write C code yourself?
Nicolas B
Nicolas B 2025년 2월 21일
Only if you can initialize separately the 3 states.
For example, in C:
bool isload = false;
int8 myState1 = 0;
int8 myState2 = 0;
if(isload == false){
myState1 = 1;
myState2 = 2;
isload = true;
}
/* my code... */

댓글을 달려면 로그인하십시오.

답변 (0개)

카테고리

Help CenterFile Exchange에서 Simulink Coder에 대해 자세히 알아보기